We- NIson Intrusment (shanghai)Limited produce chemistry analyzer MOL-300 ,the techinical parameter as following :
Analysis speed: 300TEST/H at most
Simultaneous on-line testing items: 60 for single-reagent items as maximum,dual-reagent items is reduced, sample feeding interval to be 12s Philosophy of measurement: Colorimetry (LAW OF BEER-LAMBERT ) & turbidimetry Discrete in structure :unattached Cuvette,To avoid bringing intercross pollution Testing Method: End-point, Two-point, Fixed time, Kinetic Stochastic choice:Stochastically choose the sequence of testing sample and the testing item, in while
the emergency treatment owns the priority to be tested.
Sample tray:
Sample tray capacity: 60 (Samples or sample tray may be replaced to allow more samples to be measured) all available for calibrator, quality control and emergency treatment. Sample cup:compatible with various blood sampling tubes Sample volume:2~35μl(incremental by 0.1μl),syringe capacity to be 50ul
Sample probe: Liquid level sensing, nonstick coating Pre-dilution mode: automatic dilution function to allow non-conforming sample to be automatically diluted for retesting.
Reagent tray:
Reagent tray: 60position/tray(can program for 6 reagent trays), on-line refrigeration available, dynamic display of remaining reagent
Reagent volume: 180-450µl for single-reagent items and 30-350µl for reagent II of dual-reagent items. In the case of Kinetic or two-point velocity, 150-450µl is for reagent I volume and 180-500µl(incremental by 1μl)for total reagent volume, syringe capacity to be 500ul
Reagent probe: Liquid level sensing, nonstick coating
Reaction system:
Reaction tray: 10X9, 8 clusters on line simultaneously
Cuvette replacement: Automatic loading system with rack able to hold 8 cuvette clusters (80 cuvettes in total) Cuvette: Plastic cuvette, optical length to be 6 mm Incubation temperature: 37°C, 30°C, 25°C and room temperature(Ambient temperature to be 5°C
below the set constant temperature as minimum).
Gross volume of reaction solution: 182-535μl
Mixing : Independent mixing system with nonstick-coating mixer; immediate mixing upon feeding of sample or reagent II.
Reaction time: recommended to be within 10min, subject to a maximum of 15 min. Optical system:
Light source: 13.8V,85W long-life tungsten halogen light
Testing wavelength (nm): 340, 405, 450, 510, 546, 600, 630and690
Splitting mode: Interference filter
Half-wave width: 8±2nm
Absorption range: 0-3A (0-5A, converted based on an optical length of 10mm)
Absorption resolution: 0.001A Cleaning system:
Probe cleaning: Inner and outer walls to be cleaned separately
Water consumption: 5L/H, deionized water
Operating System:
Master computer: Pentium or above, RS-232 port, CRT or LCD display Software: Windows NT (4.0 or above); Foreign languages: English and others Input devices: Keyboard, mouse Computer: Narrow space 24-needle, compatible with customizable-paper-size NT drive program. Communication interface: RS232 bidirectional standard interface
Running Conditions:
Power: AC 220V, 50Hz
Power: 800VA
Weight: 100 kg
External dimensions (mm): length743�idth1133�eight1378
|